SMOD
Sequence operating MODe
Class Sequence editor control
Description Sets the sequence mode. The SMOD? query returns the current setting of SMOD.
Command syntax SMOD mode
mode
0 = disable
1 = enable manual step mode that stops at last step
2 = enable manual step mode that wraps to first step after last step
3 = enable continuous auto stepping
Query syntax SMOD?
Query response mode
Other required
commands
The SEQL command loads the sequence and SEQU starts to run it.
Example
SEQL MY_SEQ // Load "MY_SEQ" in edit buffer
SEQU // Start running the sequence in the buffer
SMOD 3 // Set the sequence mode