Digital Video Signal Swing
Class Format parameter setting - Digital video signal
Description Sets the TMDS differential swing voltage for the digital video signal. The DVSS query
returns the current value.
The DV_Swing image can also be used to adjust the digital swing.
Command syntax DVSS voltage
voltage
0.0 to 2.0 volts differential peak-to-peak (nominally 1.000, 0.150 to 1.560 range
guaranteed)
Query syntax DVSS?
Related commands DVST, DVSC
Examples
DVSS 1.25 // sets the digital video signal swing voltage to 1.25 volts
ALLU